Part No. 4801-5138 Rev 11-05 Rollup Curtain System Page 18
Table 2
Distance Of Motor Mount Bracket From End Of Curtain
System
(Opening Size)
D
System
(Opening Size)
D
4' 75 in. (190.5 cm) 6' 99 in. (251.5 cm)
5' 87 in. (221.0 cm) 7' 111 in. (281.9 cm)
8. Pivot Gearbox Drive
IMPORTANT!
Two Systems On A Common Wall Must Meet At A Vertical Column!
If Adjacent Systems Are Installed Along A Sidewall, Space Motor Mount Brackets Equally
On Each Side Of A Vertical Column. Distance Of Separation Between Motor Mount
Brackets Should Be 3 ft. 3-1/2 in. (100 cm) Center-To-Center.
1. Close curtain to fully lowered position.
2. Position top edge of motor mount bracket even with top of curtain. Position center of motor
mount bracket at a distance D from end of curtain as shown in Fig. 8. Refer to Table 2 below to
determine distance D for system you are installing. NOTE: If two adjacent systems are installed,
equally space motor mounts on each side of a vertical column. Locate motor mounts 3 ft. 3-1/2
in. (100 cm) apart center-to-center. See Fig. 8 & Fig. 9 below.
3. Hold motor mount bracket against panel at position where bracket is to be attached (from step 2
above). Mark the four screw holes of motor mount bracket. Or use hole pattern as shown to
mark screw hole locations. Drill holes for 3/8-16 screws. See Fig. 9.
4. Firmly fasten motor mount bracket to stringer using 3/8-16 screws and nuts as shown in Fig. 9.
5. Attach motor support arm to motor using M8 screws provided. See Fig. 10.
D ± 3"
3' 3-1/2"
D
3"
FIG. 8
Placement Of
Motor Mount Brackets
Motor Mount Bracket
ertical column is
located behind panel.
See Fig. 9.
100 cm
Komentarze do niniejszej Instrukcji